Difference between revisions of "Rose-UKCA suites"
Line 5: | Line 5: | ||
====Pre-requisites==== |
====Pre-requisites==== |
||
− | Account on the Met Office Science Repository [https:code.metoffice.gov.uk (MOSRS)] for UM and Rose code, the PUMA [https://puma.nerc.ac.uk/trac/roses_puma/wiki Rose repository] (if using ''puma-'' suites) and access to the [http://www.jwcrp.org.uk/infrastructure/monsoon.asp MONSooN] HPC system.<br/> |
+ | Account on the Met Office Science Repository [https://code.metoffice.gov.uk (MOSRS)] for UM and Rose code, the PUMA [https://puma.nerc.ac.uk/trac/roses_puma/wiki Rose repository] (if using ''puma-'' suites) and access to the [http://www.jwcrp.org.uk/infrastructure/monsoon.asp MONSooN] HPC system.<br/> |
Basic knowledge about [http://metomi.github.io/rose/doc/rose.html Rose] and [https://code.metoffice.gov.uk/doc/um/vn10.2/um-training/index.html its usage with UM].<br/> |
Basic knowledge about [http://metomi.github.io/rose/doc/rose.html Rose] and [https://code.metoffice.gov.uk/doc/um/vn10.2/um-training/index.html its usage with UM].<br/> |
||
Revision as of 16:22, 6 March 2018
Rose UKCA suites on MONsooN
This page describes the Rose suites with UKCA that are installed on MONsooN.
Disclaimer: The main purpose of these suites is for model development and overall assessment of performance. Until the suites are assessed properly and released via the UKCA Release Jobs page, they should be considered as not suitable for Science applications.
Pre-requisites
Account on the Met Office Science Repository (MOSRS) for UM and Rose code, the PUMA Rose repository (if using puma- suites) and access to the MONSooN HPC system.
Basic knowledge about Rose and its usage with UM.
For the initial Rose setup and instructions on using Rose on MONSooN, see this page (requires Collaboration Twiki login).
UM11.0 (Test Suite)
This is an upgrade of the vn10.9 suite and continues to run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- StratTrop(CheST)-Columnar+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
The Offline oxidants and Strattrop-Columnar jobs include a bit-reproducibility test (16x8 vs 8x12 PEs), while the Strat+trop job includes an OpenMP (1 thread vs 2 threads) and a Restartability (NRUN vs NRUN+CRUN) test
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
UM10.9 (Test Suite)
This is an upgrade from previous versions of the suite and continues to run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- StratTrop(CheST)-Columnar+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
The Offline oxidants and Strattrop-Columnar jobs include bit-reproducibility between 16x8 vs 8x12 PEs, while the Strat+trop job includes a NRUN vs NRUN+CRUN
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
UM10.8 (Test Suite)
MONSooN: puma-aa438
MetO: mi-at557
This is an upgrade from previous versions of the suite and continues to run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
The Offline oxidants job includes bit-reproducibility between 16x8 vs 8x12 PEs (TEST_PE), while the Strat+trop job includes a NRUN vs NRUN+CRUN (CRUN_TEST)
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
UM10.7 (Test Suite)
MONSooN: puma-aa428
MetO: mi-ar330
This is an upgrade from the UM10.6 suite a test suite continues to run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
The Offline oxidants job includes bit-reproducibility between 16x8 vs 8x12 PEs (TEST_PE), while the Strat+trop job includes a NRUN vs NRUN+CRUN (CRUN_TEST)
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
UM10.6 (Test Suite)
MONSooN: puma-aa405
MetO: mi-ap240
This is an upgrade from the UM10.5 suite a test suite continues to run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
The Offline oxidants job includes bit-reproducibility between 16x8 vs 8x12 PEs (TEST_PE), while the Strat+trop job includes a NRUN vs NRUN+CRUN (CRUN_TEST)
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
UM10.5 (Test Suite)
puma-aa358: This is a simple upgrade from the UM10.4 suite a test suite continues to run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
AS for UM10.4, the Offline oxidants job includes bit-reproducibility between 16x8 vs 8x12 PEs (TEST_PE) as well as the NRUN vs CRUN, CRUN_TEST)
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
UM10.4 (Test Suite)
puma-aa322: This is a test suite based on the UKCA configurations in the UM trunk and can simultaneously run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate
The Offline oxidants job includes tests to compare between 16x8 vs 8x12 PE configurations (TEST_PE), as well as between runs composed of different segments (NRUN-CRUN, CRUN_TEST)
The main configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray.
A significant change from the UM10.3 suite is that all the tasks are run from the same base app (um), making use of optional configurations : ROSE_APP_OPT_CONF_KEYS in the suite.rc.
UM10.3
puma-aa262: This is a test suite based on the UKCA configurations in the UM trunk and can simultaneously run the following configurations at N96L85:
- StratTrop(CheST)+GLOMAP+RADAER+Activate
- Offline oxidants+GLOMAP+RADAER+Activate with two PE configurations
Both the configurations carry out a 2-day simulation that requires between 10 - 15 minutes to complete on the Cray. The CheST Configuration uses 16x8 PEs, while the Offline configuration uses 16x8 and 8x12 PEs.
UM10.2
puma-aa237: This is an UKCA StratTrop/CheST Chemistry +GLOMAP suite at N96L85 resolution. The suite is derived from the UM Global Atmosphere development suite mi-ah615, but using the StraTrop or CheST scheme instead of Offline oxidants.
The suite is set up to archive model output (to the MASS tape drive) and submit the next segment, so it can be used for performing long simulations.