This page contains details of GA7.1+StratTrop suites available.
Usage
- COPY these suites for your use rosie copy u-nnXXX
(or in Rosie GUI), rather than checking them out.This will prevent you accidentally over-writing the settings in the original suite.
- For Monsoon2
, remember to change the project-name before running (This might be set to ukca-meto by default), otherwise you are likely to see submit-failed
error messages for tasks running on the HPC.
TS2000 free-running suites
These are year-2000 atmosphere-only timeslice simulations.
UM versions | Met Office XC40 | Monsoon2 XCS | NEXCS | ARCHER |
---|---|---|---|---|
UM11.0 | u-ay770 |
u-bb055 |
u-bb056 |
u-ba915
|
UM11.1 | u-bd086 |
Will be | produced | on request |
UM11.2 | u-bd036 |
u-bd683 |
u-be045
| |
UM11.3 Bit-reprod with UM11.2 |
u-bg745 |
u-bg779 |
u-bg785
| |
UM11.4 Comparison with UM11.3 |
u-bk249 |
u-bl029 |
||
UM11.5 Comparison with UM11.4 |
u-bo717 |
u-bo741 |
||
UM11.6 Comparison with UM11.5 |
u-bs395 |
u-bs425 |
- An example vn11.2 ARCHER suite configured for a 1-day run without archiving and with manual compile is
u-be079
. A selected set of 3-hourly meaned UKCA diagnostics are also sent to the dailyUPK
stream.
TS2000 nudged suites
These are year-2000 atmosphere-only timeslice simulations nudged to ERA-Interim reanalysis. Here the nudging files will change with date rather than being a perpetual year, although the forcings are all climatologies.
Instructions for setting up an ERA dataset for perpetual year Nudging can be found here: Nudging perpetual
UM versions | Met Office XC40 | Monsoon2 XCS | NEXCS | ARCHER |
---|---|---|---|---|
UM11.0 | u-ba749 |
u-bb202 |
u-bb210
| |
UM11.1 | u-bd267 |
Will be | produced | on request |
UM11.2 | u-bd359 |
u-bd341 |
u-bd366
| |
UM11.3 | u-bh303 |
|||
UM11.4 | Will be | produced if | needed | |
UM11.5 | u-bq095 |
|||
UM11.6 | u-bt030 |
Release notes / Known Issues
All UM versions (vn10.6.1+)
- Stash items spanning
38:485 to 38:545
i.e. Aerosol surface conc., number conc., load diagnostics: Due to the way STASH is handling and processing these items -when requested using Stash time profiles like TDMPMN, TMONMN, TDAYMN- will be output as exactly 1/3rd of their actual value. Members making use of these items need to scale the values by 3.0.
All UKCA configurations till UM11.2 using ENDGame
- The Strat-trop exchange diagnostics (e.g. O3 STE 50-051) are incorrect due to errors in handling of the extra model-level (introduced under ENDGame dynamical core) during their calculation.
All UKCA configurations till UM11.6
- The O(1D) mass mixing ratio field (STASH 34997/ 51997) is incorrect due to an error in the conversion factors used in its calculation.
Testing suites
Further details on UKCA testing suites on Monsoon2 can be found at
Other Configurations and Input Files
Please see these pages for details of further UKCA configurations in use, and information about other input files:
- Other UKCA Configurations
- Other UKCA Input Files
- CMIP6 Emissions: Details of the procedure used for generation of emissions and other forcing data for UKESM1/CMIP6 expts can be found in links from this page. Wherever possible, first try to contact the creator/ reviewer of the particular dataset in case you need more information
Converting Y2000 suites to transient
Instructions for converting the above Y2000 (decadal mean forcing) suites to transient can be found here.